800 Series

*Seven meters:
     Two digital voltmeters:
     One shows operating voltage.
     One add'l voltage sensor (stator, electronics, etc.).      (The reading is accurate to one tenth of a volt.)

     Two digital ammeters:
     One shows output amperage.
     One shows rotor draw on non-integral units.

     One digital R.P.M. meter.
     One 4-1/2" diode trio condition meter.
     One 4-1/2" ripple voltage meter.

  • Tests 6, 12, 24, 30, and 32 volt units without changing batteries.
  • Resistor bank adjustable from 0-300 amps at 12 volts with load capability of one hour minimum without overheating or deterioration (Load setting may be customized as per customer's request).
  • Load timer 0-60 minutes with indicator On or Off lights.
  • A and B field circuit switch, tests alternator / generator field system (+ or-).
  • The Motor direction, CW or CCW, is reversed through a power inverter, from 0-6000 RPM in 6 seconds.
  • Two field current selector switches, high and low, with fuse protector 10 & 20 amps.
  • Heavy duty field rheostat, 300 watts. 

 

  • 3 step pulley, (3", 4", and serpentine. Other sizes available at no extra charge.)
  • Heavy duty manual vise will accommodate any type alternator.
  • Bright red indicator light displays On or Off Mode.
  • Idiot lamp for integral type alternators.
  • Heavy duty hook up leads and clamps.
  • All type of hook up leads for foreign and domestic alternators.
  • Easy service design cabinet.